Privacy and heat are different measurements

Turn a sample of switchable privacy film from clear to milky and the change is obvious from across the room. How much solar heat did that switch keep out? Researchers in Trondheim, Norway, measured the difference on a south-facing, double-glazed window. Adding the film in its clear state reduced the share of solar energy entering by 10.1 percentage points. Switching it to translucent reduced that share by another 4.6 points. (NTNU and SINTEF researchers, writing for BUILD UP)

One window, three readings

The team from the Norwegian University of Science and Technology and SINTEF reported its findings on November 13. The film was polymer-dispersed liquid crystal, or PDLC. In this version, applying power aligns the crystals and clears the view. Switching the power off scatters the light and gives the pane its frosted appearance. (NTNU and SINTEF researchers, writing for BUILD UP, SINTEF)

Share of incoming solar energy that reached the room (NTNU and SINTEF researchers, writing for BUILD UP)
Window conditionSolar heat gain (g-value)
Bare double glazing54.1%
Same glazing with film clear44.0%
Same glazing with film translucent39.4%

The g-value counts sunlight that passes through the window and heat that the glazing absorbs and releases indoors. Going from bare glass to the milky state lowered the share by 14.7 percentage points, or about 27% relative to the bare window. The clear state alone accounted for roughly two-thirds of that difference. That is why the view through a sample is a poor guide to how much heat it will keep out. (NTNU and SINTEF researchers, writing for BUILD UP, U.S. Department of Energy)

The team reports bare-glazing observations from February 15 to March 15 and film observations from July 9 to August 31. These were different seasons on the same test façade. The report calls 54.1% both measured and declared, so treat it as the study’s reported reference, not a separately verified result. Estimating a client’s annual cooling bill would also require the building’s climate and operating schedule. Heating and cooling energy use, glare and daylight are among the questions the researchers plan to study next. (NTNU and SINTEF researchers, writing for BUILD UP)

What to ask on a job

Start by finding the pane the sun actually hits. If the client wants a conference-room partition to go private, the sun may already have entered through the outside windows before it reaches that partition. A measurement from a treated exterior window answers a different job question. If the client wants privacy and less heat at an exterior window, identify the existing glass and ask for solar heat gain and visible-light figures for that glass with the proposed film in both states.

Then use the sample for the decision it can settle. Stand in the hallway, put someone inside the room and switch the pane with the intended lights on. The client can judge what a visitor can see. The paired glass-and-film figures are what belong alongside that observation in the proposal.

Sources & scope

Use the linked originals for current provider requirements. These links do not imply affiliation, endorsement or project approval.

  1. NTNU and SINTEF: PDLC films as switchable solar shadingNovember 13, 2026. Original report from the investigators. The comparison is specific to the tested glazing and dates.
    Source checked . This is our check date, not a publication date.
  2. ZEB Test Cell laboratoryDescribes the testing facility in Trondheim, Norway.
    Source checked . This is our check date, not a publication date.
  3. Solar heat gain and visible transmittanceExplains SHGC and visible transmittance as separate properties; not a certification of the tested film.
    Source checked . This is our check date, not a publication date.