Which surface is the meter reading?
Label the outside and room side in your notes before you start. In a conventional double-pane unit, surface 1 faces the weather. Surfaces 2 and 3 face the sealed cavity. Surface 4 faces the room.
The GC3200 assigns its numbers as though you are standing outside. When you turn around and read from indoors, record that direction and map the reading back to the physical pane. Its first detectable Low-E coating can hide another coating deeper in the unit.
Take a repeatable reading
Begin on the exterior. XPEL recommends the GC3200’s Laminate Mode for routine surveys. Keep the meter near the lower center, about two inches above the edge, clear of the frame and grids. Only the instrument should touch the glass. Follow EDTM’s laser safety instructions.
Record the reading direction, layers, coating locations and any error. Check from both sides for triple glazing or a detected coating. If the display reports “Exceeds Low-E Range,” or readings disagree, contact EDTM while you can still access the opening. Keep surface 4 coatings in mind before cleaning or scraping.
XPEL technical references · EDTM GC3200 information and instructions
Build a field card for one opening
Enter the pane size and, if known, the area of the entire film project. Individual pane restrictions and whole-project review are separate checks. This card records questions for the manufacturer. The chart, glazing condition and written terms still need individual review.
Opening notes
Add dimensions to calculate rectangular pane area.
Review the film and glass in XPEL’s chart, inspect the glazing and confirm the applicable written terms.
Notes stay in this page while it is open. Print or save to PDF from your browser to keep a job copy.
When area changes the review
Page 3 of XPEL’s architectural chart gives general maximums of 100 square feet for single-pane glass and 40 for dual-pane glass. It also identifies nonrectangular panes over 20 square feet and any edge over 10 feet. Individual chart columns can have tighter limits or require written review at smaller sizes.
The standard chart requires prior written approval for projects over 3,000 square feet. A smaller project is not automatically approved. For optional extended coverage, ask XPEL for the current program requirements and project-specific written terms.
XPEL current specification and warranty documents
Public manufacturer references checked November 20, 2026.