One roll, two different sets of numbers

A customer asks why a film called “35” appears in the manufacturer’s chart at both 32% and 38% visible light transmission (VLT). Which figure should go on the quote? The one that belongs to the glass you’re describing. Both are published values for the same film applied to different reference panes. The customer’s actual window is a third pane.

In its Color Stable Series technical sheet, 3M gives two sets of typical results for CS IR 35. Start at the row for bare glass, then read the row with film on that same glass. The last row below is the difference between those two solar-rejection figures.

3M CS IR 35 on two 6 mm reference panes
What was measuredClear glassAutomotive green glass
VLT, glass alone89%73%
VLT, glass with film38%32%
Total solar energy rejected, glass alone19%42%
Total solar energy rejected, glass with film46%57%
Increase in rejection on this pane27 percentage points15 percentage points

The green glass with film has the higher total rejection. The clear glass shows the larger improvement over its own starting point. Both statements can be true. Those 15 and 27 points describe changes to the two test assemblies. They do not tell the customer how many degrees cooler their parked car will be. 3M Color Stable Series, revision C, tables B and C.

Which VLT should the shop put on the quote?

Write down the product and shade, then label any performance number you show. For example, “3M CS IR 35, published VLT 38% on the manufacturer’s clear reference glass.” If a customer needs an installed reading, record the actual pane, its starting reading if known, and its finished reading when measured. A bare-window reading on the car and a published result from a lab belong in different fields.

In particular, a calculator asking for film-only VLT cannot use 38% or 32% from this example. Both numbers already include glass. Entering either alongside another glass reading counts glass twice. If the supplier does not publish a film-only value, leave that input open. For legal questions, identify the rule for the actual window and use the measurement it calls for. WindowTintLaws.com glass and film calculator.

Why don’t the infrared columns agree?

3M’s CS IR 35 row on clear glass shows 45% infrared energy rejection (IRER) and 32% infrared rejection (IRR). Its footnotes assign different meanings to those numbers. IRER covers 780 to 2,500 nanometers for film on glass and accounts for absorbed energy that can come back into the cabin as heat. This sheet’s IRR covers 900 to 1,000 nanometers and uses the film with its liner, without glass. Neither column measures total solar energy rejected (TSER). 3M’s comparison guide and metric definitions.

Another manufacturer may use a different name and method. LLumar’s North American automotive sheet lists SIRR for infrared energy that does not pass directly through the glazing across 780 to 2,500 nanometers. The same sheet lists IRER separately because the calculation accounts for absorbed and re-radiated energy. Even the same wavelength range does not make the two columns interchangeable. LLumar’s automotive data and footnotes.

What if the competing quote leaves out the test glass?

Ask for the full product and shade, the document revision, the reference glass, the test method and the exact column used. For a customer who wants heat control at a particular light level, find rows with similar finished VLT on comparable glass and compare TSER. If the glass or test differs, show the two published results with their conditions and ask the suppliers for a matching comparison before ranking the offers. If the question is how much improvement a film adds, also ask for the bare-glass baseline.

This last detail is a real sticking point for buyers. One driver had two film-on-glass heat ratings but no figure for the original glass. With that number missing, the change from the starting pane could not be calculated. Read the driver’s comparison question.

Sources & scope

These primary sources support the limited descriptions above. Standards summaries use public scope information, not the full licensed text.

  1. 3M Color Stable Series technical data, revision CMay 2024, tables B and C. Two reference-glass baselines, CS IR 35 figures and infrared test footnotes.
    Source checked . This is our check date, not a publication date.
  2. 3M automotive product comparison guideJanuary 2025. Manufacturer definitions of visible transmission, solar rejection and infrared measurements.
    Source checked . This is our check date, not a publication date.
  3. LLumar automotive window film performance data for North AmericaPerformance-sheet footnotes define IRER, SIRR and the 6 mm clear-glass basis.
    Source checked . This is our check date, not a publication date.